Raw borehole water failing 9 UK drinking water limits, with no mains to fall back on.
Farm borehole, Isle of Coll, Inner Hebrides
Key numbers
Lead: over 5 times the UK limit, now below detection
53.1 to <1.1 µg/l. The UK limit is 10
Sodium: 635.5 to 1.7
mg/l, borehole water to treated water. The UK limit is 200
Iron: 1,210 to <6
µg/l. The UK limit is 200
9 of 9
Every UK limit the borehole failed was met after treatment
A farm on the Isle of Coll, in the Inner Hebrides, has no mains water. Its private borehole failed nine UK drinking water limits at once, so the farm’s drinking water came from trips to the village tap.
We installed a WaterOne in the farm barn. On 31 August 2023 we sampled the borehole water and the treated water at the same time. Scottish Water Scientific Services, a UKAS-accredited laboratory, analysed both.
Salt, metals and colour together make this the hardest real source in our test programme. Defence and remote sites face the same mix, often with no chance to analyse the water first.
The problem
What we did
Desalination, built into one unit
The WaterOne uses Vapour Compression Distillation, the process used in desalination plants that supply drinking water around the world, built into one unit. As the water evaporates, salt, metals and colour stay behind.
Same-day testing by a UKAS-accredited laboratory
At 3 pm on 31 August 2023 we sampled the borehole water and the treated water at the same time. Scottish Water Scientific Services tested 23 parameters.
The results
Every UK limit the borehole failed, met after treatment.
Borehole water → treated water
53.1 → <1.1
Lead, µg/l. UK limit 10
31.8 → 1.3
Antimony, µg/l. UK limit 5
1,210 → <6
Iron, µg/l. UK limit 200
92.7 → <2.0
Manganese, µg/l. UK limit 50
635.5 → 1.7
Sodium, mg/l. UK limit 200
1,756 → <2
Chloride, mg/l. UK limit 250
98 → <2
Colour, mg/l Pt/Co. UK limit 20
9.6 → 7.3
pH. UK range 6.5 to 9.5
5,560 → 19
Conductivity, µS/cm at 20°C. UK limit 2,500
14.7 → 0.5
Total organic carbon, mg/l. No limit set
Ten of the 23 parameters tested. If Water took both samples at the farm at 3 pm on 31 August 2023, and Scottish Water Scientific Services, a UKAS-accredited laboratory, analysed them. The borehole water’s conductivity was above the range of the laboratory’s method, so that value is indicative. Microbiology was not tested. The results apply to the parameters measured.
Why this matters beyond one farm
Salt, metals and colour normally need different treatment stages, chosen after the water has been analysed. Distillation handled them all together, which is what a unit sent to an unknown source has to do.
Do you need to treat challenging water sources?
Tell us where your water comes from and what you need it for. We will tell you whether a WaterOne can treat it.
Prefer to talk? Book a call
sales@if-water.com






